Wire gauge table (copper wires)

Wire gauge table (copper wires)

Published on Oct 27, 2024 by Skipper

Understanding Wire Gauge: A Comprehensive Guide

When it comes to electrical wiring, the thickness of the wire is crucial for ensuring safety and efficiency. The wire gauge, or the diameter of the wire, determines its current-carrying capacity and resistance. Here’s a closer look at what wire gauge means and how to use the wire gauge table effectively.

What is Wire Gauge?

Wire gauge refers to the physical size of the wire, which inversely relates to the number of the gauge. The smaller the gauge number, the thicker the wire. For example, a 1 gauge wire is much thicker than a 20 gauge wire.

Using the Wire Gauge Table The wire gauge table provides essential information for electricians and engineers. It lists the gauge number, diameter in millimeters, area in square millimeters, resistance per meter at 20°C, and the changes in diameter with different types of wire coverings (fine, medium, and thick).

Wire gauge table (for copper wires)

GuageDiameterAreaR/m Ohm
Resistance per meter
Fine CoveringMedium CoveringThick Covering
AWGmmSq mm@20CGrade -IGrade -IIGrade -III
17.6245.5810.000380.0507.6700.0957.7150.1417.761
27.0138.5750.000450.0507.0600.0957.1050.1417.151
36.432.1540.000540.0496.4490.0936.4930.1386.538
45.8927.2330.000630.0485.9380.0915.9810.1366.026
55.3822.7210.000760.0485.4280.0915.4710.1365.516
64.8818.6940.000920.0484.9280.0914.9710.1365.016
74.4715.6850.001100.0474.5170.0894.5590.1334.603
84.0612.9400.001330.0494.1090.0934.1530.1384.198
93.6610.5160.001640.0473.7070.0893.7490.1333.793
103.258.2920.002080.0463.2960.0873.3370.1303.380
112.956.8310.002520.0452.9950.0853.0350.1273.077
122.645.4710.003150.0432.6830.0812.7210.1222.762
12.52.494.8670.003540.0432.5330.0812.5710.1222.612
132.344.2980.004010.0422.3820.0802.4200.1192.459
13.52.1853.7480.004600.0422.2270.0802.2650.1192.304
142.033.2350.005330.0412.0710.0782.1080.1162.146
14.51.932.9240.005900.0411.9710.0782.0080.1162.046
151.832.6290.006560.0401.8700.0761.9060.1131.943
15.51.732.3490.007340.0401.7700.0761.8060.1131.843
161.632.0860.008270.0391.6690.0741.7040.1101.740
16.51.531.8380.009380.0391.5690.0741.6040.1101.640
171.421.5830.010890.0381.4580.0721.4920.1071.527
17.51.321.3680.012610.0381.3580.0721.3920.1071.427
181.221.1680.014760.0351.2550.0661.2860.0991.319
18.51.120.9850.017510.0351.1550.0661.1860.0991.219
191.020.8170.021120.0341.0540.0641.0840.0961.116
19.50.9650.7310.023590.0340.9990.0641.0290.0961.061
200.9140.6560.026300.0340.9480.0640.9780.0961.010
20.50.8630.5850.029500.0340.8970.0640.9270.0960.959
210.8130.51890.033240.0320.8450.0610.8740.0900.903
21.50.7610.45460.037930.0320.7930.0610.8220.0900.851
220.7110.39680.043460.0300.7410.0570.7680.0850.796
22.50.6610.34300.050280.0300.6910.0570.7180.0850.746
230.610.29210.059040.0270.6370.0510.6610.0760.686
23.50.580.26410.065300.0270.6070.0510.6310.0760.656
240.5590.24530.070300.0250.5840.0470.6060.0710.630
24.50.5230.21470.080310.0250.5480.0470.5700.0710.594
250.5080.20260.085130.0250.5330.0470.5550.0710.579
260.4570.16390.105190.0240.4810.0450.5020.0680.525
270.4170.13650.126330.0220.4390.0420.4590.0620.479
280.3760.11100.155390.0210.3970.0400.4160.0590.435
290.3450.09340.184570.0200.3650.0380.3830.0570.402
300.3150.07790.221400.0190.3340.0360.3510.0540.369
310.2950.06830.252430.0190.3140.0360.3310.0540.349
320.2740.05890.292610.0180.2920.0340.3080.0510.325
330.2540.05060.340510.0180.2720.0340.2880.0510.305
340.2340.04300.401200.0170.2510.0320.2660.0480.282
350.2130.03560.484210.0150.2280.0280.2410.0420.255
360.1930.02920.589760.0140.2070.0270.2200.0400.233
370.1730.02350.734010.0130.1860.0250.1980.0370.210
380.1520.01810.950840.0120.1640.0230.1750.0340.186
390.1320.01371.260800.0110.1430.0210.1530.0310.163
400.1220.01171.475960.0100.1320.0190.1410.0280.150
410.1120.00981.751290.0090.1210.0170.1290.0250.137
420.1020.00822.111510.0090.1110.0170.1190.0250.127
430.09120.00652.641220.0080.0990.0150.1060.0230.114
440.08120.00523.331820.0080.0890.0150.0960.0230.104
450.0710.00404.357900.0080.0790.0150.0860.0230.094
460.0610.00295.903830.0080.0690.0150.0760.0230.084
470.0510.0020418.446040.0510.0000.0510.0000.051
480.0410.00131913.068500.0410.0000.0410.0000.041
490.030.0007024.409050.0300.0000.0300.0000.030
500.0250.00049035.149040.0250.0000.0250.0000.025

Key Takeaways from the Table

Thicker Wires Carry More Current: As the gauge number decreases, the wire’s diameter and area increase, allowing it to carry more current with less resistance.

Resistance Matters: The resistance per meter is critical for calculating voltage drops across long distances. Lower resistance means less energy lost as heat.

Covering Affects Diameter: The type of covering on the wire affects its overall diameter, which is important for fitting the wire through conduits and connectors.

What is AWG (American Standard Gauge)?

AWG is a standardized wire gauge system. It’s used for determining the diameters of round, solid, nonferrous, electrically conducting wires. The AWG system is based on a logarithmic scale, where the gauge number is inversely related to the diameter of the wire. This means that as the gauge number increases, the wire diameter decreases.

Why AWG is Used

Standardization: AWG provides a consistent measurement system for wire thickness, which facilitates the manufacturing and selection of wires for specific purposes.

Electrical Performance: The gauge of a wire affects its current-carrying capacity and resistance. AWG helps in selecting the appropriate wire size to ensure that electrical systems operate efficiently and safely.

Compatibility: Using a standardized gauge system ensures that components such as electrical connectors and conduits are compatible with the wire sizes used.

How to select a wire size best suited to your application?

Transformers (such as current transformers):

  1. Determine Transformer Specifications:

    • Before choosing a wire gauge, you need to know the transformer specifications:
      • Primary Voltage (Vp): The voltage applied to the primary winding.
      • Secondary Voltage (Vs): The desired output voltage from the secondary winding.
      • Secondary Current (Is): The current flowing through the secondary winding.
      • Working Time: Consider how long the transformer will operate (e.g., 4 hours, 6 hours, or 12 hours).
  2. Calculate Primary Current (Ip):

    • Use the formula: Current Ratio.
    • This gives you the current in the primary winding.
  3. Determine Turns Ratio:

    • Calculate the turns ratio (Np/Ns) based on the voltage ratio:
      • Turn ratio
    • The turns ratio determines the number of turns in the primary (Np) and secondary (Ns) windings.
  4. Select Wire Gauge:

    • Use the wire gauge table (such as the American Wire Gauge - AWG) to find suitable wire sizes.
    • Consider the following factors:
      • Current Density: The wire gauge should handle the current without overheating. A common guideline is to use a current density of around 2.5 A/mm².
      • Installation Space: Choose a wire size that fits within the available space in the transformer.
      • Insulation: Consider the insulation thickness when calculating the overall diameter of the wire.
  5. Example Calculation:

    • Let’s say you have a transformer with the following specifications:
      • Primary Voltage (Vp): 220 V
      • Secondary Voltage (Vs): 13 V (center-tapped for 30-0-30 V)
      • Secondary Current (Is): 7 A
    • Calculate the primary current:
      • Primary Current Calculation
    • Determine the turns ratio:
    • Turn Ratio
      • Use a practical turns ratio (e.g., 17:1).
    • Calculate the primary and secondary turns:
      • Primary Turns (Np): (Np = 17 times 220 = 3740)
      • Secondary Turns (Ns): (Ns = 17 times 13 = 221)
    • Refer to the wire gauge table to select suitable wire sizes for the primary and secondary windings.

Conclusion

The wire gauge table is an indispensable tool in the electrical industry. By understanding and utilizing the information it provides, professionals can ensure that they choose the right wire size for their specific needs, leading to safer and more efficient electrical systems. Hopefully the above table has helped you in some way.

Remember, always consult a professional when dealing with electrical wiring to avoid any potential hazards. Safety first!